Electromagnetic Compatibility (EMC)

$
0
0

A comprehensive range of EMC chambers, test rooms, and equipment.

Airbus Defence and Space test laboratories have a wide range of the latest technology in EMC test equipment to cover all of your test needs.

We have many years of experience providing EMC testing and have developed our facilities and expertise to provide accurate testing for military, commercial and space products.

Our broad range of facilities and flexible engineers allow testing to be carried out both on site and remotely with our mobile test equipment.

Capabilities: Chamber 3 - Screened Test Chamber

--> Emissions Testing from 20Hz to 40 GHz

--> Susceptibility Testing from 20Hz TO 40GHz up to field levels of 150V/m

--> Pre-compliance test for a majority of commercial standards

--> 10m CISPR 16 Semi-Anechoic Chamber

--> 3m CISPR 16 Semi-Anechoic Chamber

--> Mil Std 461 Test Chambers

--> General Purpose Screened Rooms

--> Dimensions: 3m(L) x 3.8m(W) x 2.7m(H)

--> Access: Single personnel door

--> Screening Effectiveness: Better than 100dBup to 40GHz

--> Air conditioned

--> Tests accommodated:

--> Military (MIL 461)

Chamber 1 - Screened Test Chamber Triton Range -

--> Dimensions : 4m(L) x 4m(W) x 4.5m(H)

--> Access : Single and Double Personnel doors.

Double: 3.0m x 3.0m

--> Screening Effectiveness : Better than 100dB up to

40GHz

--> Air conditioned

--> Class 3 (100,000 clean room standard)

--> Tests accommodated:

--> Military (MIL 461)

A multi-purpose Fully or Semi-Anechoic Test Facility:

--> 10m CISPR 16 Semi-Anechoic Chamber

--> Spherical Antenna Test Range

--> Dimensions: 30m(L) x 15m(W) x 15m(H)

--> Turntable: 8m Diameter. 10 tonne static loading, 2

tonne rotation loading.

--> Access: 8m x 8m Swing Doors, External Hydraulic

Lift for seamless entry of equipment up to 10 tonne.

Single personnel door also.

--> Screening effectiveness: Better than 100dB below

18GHz, Better than 60dB from 18 to 40GHz

---> Air Conditioned

--> Class 3 (100,000 clean room standard)

--> Adjacent Screened Control/Support test chamber

 

Chamber 2 - Screened Test Chamber Tests accommodated: --> Dimensions : 6.41m(L) x 4.88m(W) x 3.66m(H)--> Access: Double personnel door 3.05mx 3.20m--> Screening Effectiveness : Better than 100dB up to40GHz--> Air conditioned--> Tests accommodated:--> Military (MIL 461) --> Commercial (CISPR 16, EN55022, EN61000-6-x) --> Military (MIL 461) --> Antenna measurements of Pattern, Gain and Return Loss --> Payload EMC Testing